Two-dimensional echocardiographic image texture analysis: Reduction of regional variability using polar coordinates

Phil Aylward, B. N. Knosp, D. D. McPherson, D. A. Eltoft, C. E. Yurkonis, J. A. Bean, D. J. Skorton, S. M. Collins

Research output: Contribution to journalArticle

1 Citation (Scopus)

Abstract

Factors inherent to the ultrasound imaging system can influence quantitative ultrasound image texture and may produce changes that mask or mimic those due to alterations in tissue structure. In this study, we assessed the effect of the method of image data acquisition and analysis on the variations in quantitative texture measures that occurred solely due to the position of a region of interest (ROI) within the field of view. When ROI's, which varied in range and azimuth within the image of a tissue equivalent phantom (of uniform composition), were assessed by conventional analysis of scan-converted (rectangular coordinate) data, over 50 percent of all texture measures showed significant differences. Pseudo polar analysis reduced the number of texture measures showing regional variation by 80 percent (p < 0.01) and true polar coordinate data analysis reduced the number by 74 percent (p < 0.01). True polar analysis completely abolished differences in texture measures between ROI's separated in azimuth. Acquisition and analysis of tissue texture data using polar coordinates should allow a more definitive identification of abnormal tissue.

LanguageEnglish
Pages60-73
Number of pages14
JournalUltrasonic Imaging
Volume7
Issue number1
DOIs
Publication statusPublished - 4 Sep 1985
Externally publishedYes

ASJC Scopus subject areas

  • Radiological and Ultrasound Technology
  • Radiology Nuclear Medicine and imaging

Cite this

Aylward, P., Knosp, B. N., McPherson, D. D., Eltoft, D. A., Yurkonis, C. E., Bean, J. A., ... Collins, S. M. (1985). Two-dimensional echocardiographic image texture analysis: Reduction of regional variability using polar coordinates. Ultrasonic Imaging, 7(1), 60-73. https://doi.org/10.1016/0161-7346(85)90016-1
Aylward, Phil ; Knosp, B. N. ; McPherson, D. D. ; Eltoft, D. A. ; Yurkonis, C. E. ; Bean, J. A. ; Skorton, D. J. ; Collins, S. M. / Two-dimensional echocardiographic image texture analysis : Reduction of regional variability using polar coordinates. In: Ultrasonic Imaging. 1985 ; Vol. 7, No. 1. pp. 60-73.
@article{0f9d9af90eb641ee97744418a4d673d1,
title = "Two-dimensional echocardiographic image texture analysis: Reduction of regional variability using polar coordinates",
abstract = "Factors inherent to the ultrasound imaging system can influence quantitative ultrasound image texture and may produce changes that mask or mimic those due to alterations in tissue structure. In this study, we assessed the effect of the method of image data acquisition and analysis on the variations in quantitative texture measures that occurred solely due to the position of a region of interest (ROI) within the field of view. When ROI's, which varied in range and azimuth within the image of a tissue equivalent phantom (of uniform composition), were assessed by conventional analysis of scan-converted (rectangular coordinate) data, over 50 percent of all texture measures showed significant differences. Pseudo polar analysis reduced the number of texture measures showing regional variation by 80 percent (p < 0.01) and true polar coordinate data analysis reduced the number by 74 percent (p < 0.01). True polar analysis completely abolished differences in texture measures between ROI's separated in azimuth. Acquisition and analysis of tissue texture data using polar coordinates should allow a more definitive identification of abnormal tissue.",
author = "Phil Aylward and Knosp, {B. N.} and McPherson, {D. D.} and Eltoft, {D. A.} and Yurkonis, {C. E.} and Bean, {J. A.} and Skorton, {D. J.} and Collins, {S. M.}",
year = "1985",
month = "9",
day = "4",
doi = "10.1016/0161-7346(85)90016-1",
language = "English",
volume = "7",
pages = "60--73",
journal = "Ultrasonic Imaging",
issn = "0161-7346",
publisher = "Dynamedia Inc.",
number = "1",

}

Aylward, P, Knosp, BN, McPherson, DD, Eltoft, DA, Yurkonis, CE, Bean, JA, Skorton, DJ & Collins, SM 1985, 'Two-dimensional echocardiographic image texture analysis: Reduction of regional variability using polar coordinates', Ultrasonic Imaging, vol. 7, no. 1, pp. 60-73. https://doi.org/10.1016/0161-7346(85)90016-1

Two-dimensional echocardiographic image texture analysis : Reduction of regional variability using polar coordinates. / Aylward, Phil; Knosp, B. N.; McPherson, D. D.; Eltoft, D. A.; Yurkonis, C. E.; Bean, J. A.; Skorton, D. J.; Collins, S. M.

In: Ultrasonic Imaging, Vol. 7, No. 1, 04.09.1985, p. 60-73.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Two-dimensional echocardiographic image texture analysis

T2 - Ultrasonic Imaging

AU - Aylward, Phil

AU - Knosp, B. N.

AU - McPherson, D. D.

AU - Eltoft, D. A.

AU - Yurkonis, C. E.

AU - Bean, J. A.

AU - Skorton, D. J.

AU - Collins, S. M.

PY - 1985/9/4

Y1 - 1985/9/4

N2 - Factors inherent to the ultrasound imaging system can influence quantitative ultrasound image texture and may produce changes that mask or mimic those due to alterations in tissue structure. In this study, we assessed the effect of the method of image data acquisition and analysis on the variations in quantitative texture measures that occurred solely due to the position of a region of interest (ROI) within the field of view. When ROI's, which varied in range and azimuth within the image of a tissue equivalent phantom (of uniform composition), were assessed by conventional analysis of scan-converted (rectangular coordinate) data, over 50 percent of all texture measures showed significant differences. Pseudo polar analysis reduced the number of texture measures showing regional variation by 80 percent (p < 0.01) and true polar coordinate data analysis reduced the number by 74 percent (p < 0.01). True polar analysis completely abolished differences in texture measures between ROI's separated in azimuth. Acquisition and analysis of tissue texture data using polar coordinates should allow a more definitive identification of abnormal tissue.

AB - Factors inherent to the ultrasound imaging system can influence quantitative ultrasound image texture and may produce changes that mask or mimic those due to alterations in tissue structure. In this study, we assessed the effect of the method of image data acquisition and analysis on the variations in quantitative texture measures that occurred solely due to the position of a region of interest (ROI) within the field of view. When ROI's, which varied in range and azimuth within the image of a tissue equivalent phantom (of uniform composition), were assessed by conventional analysis of scan-converted (rectangular coordinate) data, over 50 percent of all texture measures showed significant differences. Pseudo polar analysis reduced the number of texture measures showing regional variation by 80 percent (p < 0.01) and true polar coordinate data analysis reduced the number by 74 percent (p < 0.01). True polar analysis completely abolished differences in texture measures between ROI's separated in azimuth. Acquisition and analysis of tissue texture data using polar coordinates should allow a more definitive identification of abnormal tissue.

UR - http://www.scopus.com/inward/record.url?scp=84970504612&partnerID=8YFLogxK

U2 - 10.1016/0161-7346(85)90016-1

DO - 10.1016/0161-7346(85)90016-1

M3 - Article

VL - 7

SP - 60

EP - 73

JO - Ultrasonic Imaging

JF - Ultrasonic Imaging

SN - 0161-7346

IS - 1

ER -