Povidone-iodine irrigation - a possible alternative to lead extraction

Rishi Puri, Peter J. Psaltis, Adam J. Nelson, Prashanthan Sanders, Glenn D. Young

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

Pocket infection and erosion remain the commonest (class 1) indication for pacemaker (PM) or implantable cardiac defibrillator (ICD) lead extraction [1]. However, tranvenous lead extraction is not without significant risk of serious complications, particularly in patients with chronically implanted leads or ICD leads specifically. The paucity of cardiologists adequately experienced to undertake this high-risk procedure also means that its availability is limited to relatively few specialist institutions, yet more conservative 'lead-preserving' treatment options have not been well-reported. We describe the first reported case of a chronically eroded and infected ICD generator, managed conservatively with 5-days of povidone-iodine closed irrigation, followed by re-implantation of a new ICD on the contralateral side. With satisfactory long-term followup, this successfully averted the need for lead extraction in our elderly patient. We advocate the need for formal prospective evaluation of conservative therapeutic strategies of PM and ICD pocket infections. Although not gold standard, it provides an important therapeutic alternative in resource-limited areas.

LanguageEnglish
Pages115-119
Number of pages5
JournalIndian Pacing and Electrophysiology Journal
Volume11
Issue number4
Publication statusPublished - 1 Jul 2011
Externally publishedYes

Keywords

  • Device erosion
  • ICD/PM
  • Povidone-iodine

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine
  • Physiology (medical)

Cite this

Puri, Rishi ; Psaltis, Peter J. ; Nelson, Adam J. ; Sanders, Prashanthan ; Young, Glenn D. / Povidone-iodine irrigation - a possible alternative to lead extraction. In: Indian Pacing and Electrophysiology Journal. 2011 ; Vol. 11, No. 4. pp. 115-119.
@article{bb03c09ef52c45b9b26f80e08302118d,
title = "Povidone-iodine irrigation - a possible alternative to lead extraction",
abstract = "Pocket infection and erosion remain the commonest (class 1) indication for pacemaker (PM) or implantable cardiac defibrillator (ICD) lead extraction [1]. However, tranvenous lead extraction is not without significant risk of serious complications, particularly in patients with chronically implanted leads or ICD leads specifically. The paucity of cardiologists adequately experienced to undertake this high-risk procedure also means that its availability is limited to relatively few specialist institutions, yet more conservative 'lead-preserving' treatment options have not been well-reported. We describe the first reported case of a chronically eroded and infected ICD generator, managed conservatively with 5-days of povidone-iodine closed irrigation, followed by re-implantation of a new ICD on the contralateral side. With satisfactory long-term followup, this successfully averted the need for lead extraction in our elderly patient. We advocate the need for formal prospective evaluation of conservative therapeutic strategies of PM and ICD pocket infections. Although not gold standard, it provides an important therapeutic alternative in resource-limited areas.",
keywords = "Device erosion, ICD/PM, Povidone-iodine",
author = "Rishi Puri and Psaltis, {Peter J.} and Nelson, {Adam J.} and Prashanthan Sanders and Young, {Glenn D.}",
year = "2011",
month = "7",
day = "1",
language = "English",
volume = "11",
pages = "115--119",
journal = "Indian Pacing and Electrophysiology Journal",
issn = "0972-6292",
publisher = "Indian Pacing and Electrophysiology Group",
number = "4",

}

Puri, R, Psaltis, PJ, Nelson, AJ, Sanders, P & Young, GD 2011, 'Povidone-iodine irrigation - a possible alternative to lead extraction', Indian Pacing and Electrophysiology Journal, vol. 11, no. 4, pp. 115-119.

Povidone-iodine irrigation - a possible alternative to lead extraction. / Puri, Rishi; Psaltis, Peter J.; Nelson, Adam J.; Sanders, Prashanthan; Young, Glenn D.

In: Indian Pacing and Electrophysiology Journal, Vol. 11, No. 4, 01.07.2011, p. 115-119.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Povidone-iodine irrigation - a possible alternative to lead extraction

AU - Puri, Rishi

AU - Psaltis, Peter J.

AU - Nelson, Adam J.

AU - Sanders, Prashanthan

AU - Young, Glenn D.

PY - 2011/7/1

Y1 - 2011/7/1

N2 - Pocket infection and erosion remain the commonest (class 1) indication for pacemaker (PM) or implantable cardiac defibrillator (ICD) lead extraction [1]. However, tranvenous lead extraction is not without significant risk of serious complications, particularly in patients with chronically implanted leads or ICD leads specifically. The paucity of cardiologists adequately experienced to undertake this high-risk procedure also means that its availability is limited to relatively few specialist institutions, yet more conservative 'lead-preserving' treatment options have not been well-reported. We describe the first reported case of a chronically eroded and infected ICD generator, managed conservatively with 5-days of povidone-iodine closed irrigation, followed by re-implantation of a new ICD on the contralateral side. With satisfactory long-term followup, this successfully averted the need for lead extraction in our elderly patient. We advocate the need for formal prospective evaluation of conservative therapeutic strategies of PM and ICD pocket infections. Although not gold standard, it provides an important therapeutic alternative in resource-limited areas.

AB - Pocket infection and erosion remain the commonest (class 1) indication for pacemaker (PM) or implantable cardiac defibrillator (ICD) lead extraction [1]. However, tranvenous lead extraction is not without significant risk of serious complications, particularly in patients with chronically implanted leads or ICD leads specifically. The paucity of cardiologists adequately experienced to undertake this high-risk procedure also means that its availability is limited to relatively few specialist institutions, yet more conservative 'lead-preserving' treatment options have not been well-reported. We describe the first reported case of a chronically eroded and infected ICD generator, managed conservatively with 5-days of povidone-iodine closed irrigation, followed by re-implantation of a new ICD on the contralateral side. With satisfactory long-term followup, this successfully averted the need for lead extraction in our elderly patient. We advocate the need for formal prospective evaluation of conservative therapeutic strategies of PM and ICD pocket infections. Although not gold standard, it provides an important therapeutic alternative in resource-limited areas.

KW - Device erosion

KW - ICD/PM

KW - Povidone-iodine

UR - http://www.scopus.com/inward/record.url?scp=79960111459&partnerID=8YFLogxK

M3 - Article

VL - 11

SP - 115

EP - 119

JO - Indian Pacing and Electrophysiology Journal

T2 - Indian Pacing and Electrophysiology Journal

JF - Indian Pacing and Electrophysiology Journal

SN - 0972-6292

IS - 4

ER -