Oesophageal intubation: An analysis of 2000 incident reports

R. Holland, R. K. Webb, W. B. Runciman

Research output: Contribution to journalArticle

54 Citations (Scopus)

Abstract

There were 35 oesophageal intubations in the first 2000 incidents reported to the Australian Incident Monitoring Study (AIMS). These reports confirm existing impressions that misplacement of the endotracheal tube can occur in trained as well as untrained hands, and that auscultation is an unreliable test. On the other hand, the value of capnography is emphasised, with no false positives in the 16 cases in which the instrument was used. There was one false negative. Over the 4 years of the AIMS study, reports have declined in frequency. It is possible that the early detection of oesophageal intubation by capnography has altered its status to the extent that anaesthetists no longer regard it as a 'critical' incident. It is highly recommended that the presence of the expected concentration of carbon dioxide in expired air be confirmed by capnography immediately after any endotracheal intubation.

LanguageEnglish
Pages608-610
Number of pages3
JournalAnaesthesia and Intensive Care
Volume21
Issue number5
Publication statusPublished - 1993
Externally publishedYes

Keywords

  • Anaesthesia
  • Complications

ASJC Scopus subject areas

  • Anesthesiology and Pain Medicine

Cite this

Holland, R., Webb, R. K., & Runciman, W. B. (1993). Oesophageal intubation: An analysis of 2000 incident reports. Anaesthesia and Intensive Care, 21(5), 608-610.
Holland, R. ; Webb, R. K. ; Runciman, W. B. / Oesophageal intubation : An analysis of 2000 incident reports. In: Anaesthesia and Intensive Care. 1993 ; Vol. 21, No. 5. pp. 608-610.
@article{42c3489d474c4487991234460bf44ce6,
title = "Oesophageal intubation: An analysis of 2000 incident reports",
abstract = "There were 35 oesophageal intubations in the first 2000 incidents reported to the Australian Incident Monitoring Study (AIMS). These reports confirm existing impressions that misplacement of the endotracheal tube can occur in trained as well as untrained hands, and that auscultation is an unreliable test. On the other hand, the value of capnography is emphasised, with no false positives in the 16 cases in which the instrument was used. There was one false negative. Over the 4 years of the AIMS study, reports have declined in frequency. It is possible that the early detection of oesophageal intubation by capnography has altered its status to the extent that anaesthetists no longer regard it as a 'critical' incident. It is highly recommended that the presence of the expected concentration of carbon dioxide in expired air be confirmed by capnography immediately after any endotracheal intubation.",
keywords = "Anaesthesia, Complications",
author = "R. Holland and Webb, {R. K.} and Runciman, {W. B.}",
year = "1993",
language = "English",
volume = "21",
pages = "608--610",
journal = "Anaesthesia and Intensive Care",
issn = "0310-057X",
publisher = "Australian Society of Anaesthetists",
number = "5",

}

Holland, R, Webb, RK & Runciman, WB 1993, 'Oesophageal intubation: An analysis of 2000 incident reports', Anaesthesia and Intensive Care, vol. 21, no. 5, pp. 608-610.

Oesophageal intubation : An analysis of 2000 incident reports. / Holland, R.; Webb, R. K.; Runciman, W. B.

In: Anaesthesia and Intensive Care, Vol. 21, No. 5, 1993, p. 608-610.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Oesophageal intubation

T2 - Anaesthesia and Intensive Care

AU - Holland, R.

AU - Webb, R. K.

AU - Runciman, W. B.

PY - 1993

Y1 - 1993

N2 - There were 35 oesophageal intubations in the first 2000 incidents reported to the Australian Incident Monitoring Study (AIMS). These reports confirm existing impressions that misplacement of the endotracheal tube can occur in trained as well as untrained hands, and that auscultation is an unreliable test. On the other hand, the value of capnography is emphasised, with no false positives in the 16 cases in which the instrument was used. There was one false negative. Over the 4 years of the AIMS study, reports have declined in frequency. It is possible that the early detection of oesophageal intubation by capnography has altered its status to the extent that anaesthetists no longer regard it as a 'critical' incident. It is highly recommended that the presence of the expected concentration of carbon dioxide in expired air be confirmed by capnography immediately after any endotracheal intubation.

AB - There were 35 oesophageal intubations in the first 2000 incidents reported to the Australian Incident Monitoring Study (AIMS). These reports confirm existing impressions that misplacement of the endotracheal tube can occur in trained as well as untrained hands, and that auscultation is an unreliable test. On the other hand, the value of capnography is emphasised, with no false positives in the 16 cases in which the instrument was used. There was one false negative. Over the 4 years of the AIMS study, reports have declined in frequency. It is possible that the early detection of oesophageal intubation by capnography has altered its status to the extent that anaesthetists no longer regard it as a 'critical' incident. It is highly recommended that the presence of the expected concentration of carbon dioxide in expired air be confirmed by capnography immediately after any endotracheal intubation.

KW - Anaesthesia

KW - Complications

UR - http://www.scopus.com/inward/record.url?scp=0027672059&partnerID=8YFLogxK

M3 - Article

VL - 21

SP - 608

EP - 610

JO - Anaesthesia and Intensive Care

JF - Anaesthesia and Intensive Care

SN - 0310-057X

IS - 5

ER -